Powerwall Control (experimental)
Overview
Section titled “Overview”Powerwall Control is experimental.
Powerwall Control charges, discharges, or holds the Powerwall with direct commands. It can be started manually from the Automation > Configuration tab, in the Powerwall Control (experimental) card, by an automation, or by the Octopus integrations. When it ends, the Powerwall goes back to normal operation.
Powerwall Control does not change the backup reserve or the utility rate plan. This makes Powerwall Control more reliable than changing those settings, with less risk of the Powerwall being left in the wrong configuration. On most systems, it also charges and discharges faster.
Powerwall Control requires a Netzero subscription and a paired Powerwall.
Actions
Section titled “Actions”Charge
Section titled “Charge”Charge charges the Powerwall from solar and the grid up to the target charge level, then holds the charge until the session ends.
Charge turns Grid charging on if it is off, and it stays on after the session. The Charge option is not shown when Tesla does not allow grid charging to be turned on for the system.
Discharge
Section titled “Discharge”Discharge discharges the Powerwall to the home and the grid down to the target charge level, then the Powerwall goes back to normal operation. Energy the home does not use is exported to the grid. The target cannot be set below the backup reserve.
Discharge sets Energy exports to Everything (solar and battery) if it is set otherwise, and it stays that way after the session.
The Discharge option is only shown when the grid connection permits exporting stored energy, as for Powerwall grid export.
Preserve charge
Section titled “Preserve charge”Preserve charge keeps the Powerwall from charging or discharging, so the home runs from solar and the grid. Use it to keep the Powerwall from discharging into an electric vehicle, for example. Solar energy the home does not use goes to the grid instead of the Powerwall.
Starting and stopping
Section titled “Starting and stopping”Pick an action, a duration (5 to 240 minutes), and for Charge and Discharge a target charge level, then tap Start. While a session runs, the card shows the charging or discharging power, the time remaining, and the Powerwall charge level. Tap Stop to end it early.
A session ends as soon as any one of the following happens:
- it is stopped manually,
- the duration has elapsed,
- a discharge reaches its target charge level, or
- the Powerwall stops accepting the commands.
The card also shows a session started by an automation or an Octopus integration, and who started it. Stop ends a session started by an automation, but not one started by an Octopus integration, which ends with its slot or session.
Automations
Section titled “Automations”The Powerwall Control (experimental) automation action is listed first among the automation actions. It has four options, with nothing else to set:
- Charge charges from solar and the grid to 100%, then holds the charge. On a full Powerwall, it holds the charge straight away.
- Discharge discharges to the home and the grid, down to the backup reserve.
- Preserve charge keeps the Powerwall from charging or discharging.
- Resume Powerwall control ends the session, so the Powerwall returns to its operational mode and settings. It does nothing when no session is running.
The options are only offered for a system with a paired Powerwall, and Charge and Discharge only where the grid connection permits them, as for the card.
How an automation session ends
Section titled “How an automation session ends”An automation session has no duration or target. It runs until an automation with Resume Powerwall control ends it, so a session is normally set up with two automations: one that starts it and one that ends it. Without one, a charge or preserve session ends after 12 hours, and a discharge after 4 hours or at the backup reserve.
A discharge stops at the backup reserve. To stop at another level, set the backup reserve in the same automation: it applies from the start of the session. A backup reserve raised later still raises the level the discharge stops at.
When a session ends on its own (at the time limit, at the backup reserve, because the Powerwall stopped accepting the commands, or, for a discharge, because the system went off-grid), a notification says why, and the end is listed in Automation > Past Runs.
Example, discharging during the evening peak down to 30%:
Every day at 4:00 PM: Powerwall Control: Discharge; Set backup reserve to: 30%; Set energy exports to: Everything (solar and battery).Every day at 7:00 PM: Resume Powerwall control.Example, charging to about 80% at the start of a cheap period:
Every day at 12:30 AM, if Powerwall is discharged down to 79%: Powerwall Control: Charge; Set grid charging to: Enabled.When Powerwall is charged up to 80%: Resume Powerwall control.The first automation is a merged automation of a time trigger and a charge level condition, so the charge only starts below 80%. The second one ends it when the charge rises above 80%. Tesla reports the charge level every few minutes, so the Powerwall may charge a few percent past the target.
Charge also sets Grid charging to Enabled, and Discharge sets Energy exports to Everything (solar and battery), in the same automation. These settings cannot be changed there, and they stay when the session ends.
Replacing a running session
Section titled “Replacing a running session”Only one session runs at a time:
- An automation with another option replaces the running session straight away, whether it was started by another automation or from the card. An automation with the option that is already running does nothing.
- The card cannot start a session while another one runs. Stop it first.
- While an Octopus integration runs a session, automations and the card cannot start or end a session.
Octopus integrations
Section titled “Octopus integrations”The Intelligent Octopus Go, Weekend Happy Hours, and Power Down session integrations can use Powerwall Control instead of changing the Powerwall settings. Choose Powerwall Control (experimental) as the charging or export method in Settings > Utility Rate Plan.
A session started by an Octopus integration takes over from a session started by an automation or from the card, and runs until the slot or session ends.
How it works
Section titled “How it works”Powerwall Control charges or discharges at up to 10 kW, or less when the Powerwall power rating or a grid import or export limit is lower. The 10 kW limit cannot be increased.
Powerwall grid export can export more on larger systems, such as those with several Powerwalls, or under a grid export limit: start it from the Powerwall Grid Export card on the Automation > Configuration tab, or add it to an automation. To charge from the grid faster, set the backup reserve to 100% with Grid charging set to Enabled, and the Powerwall charges at its own rate.
- Only one session runs at a time. A session cannot be started from the card or by an automation while a Powerwall grid export or an Intelligent Octopus Go dispatch is running, and a Powerwall grid export cannot be started while a session runs.
- Automations are not paused during a session. Other automations that change Powerwall settings take effect when the session ends.
- A session started while a VPP event controls the Powerwall is refused. A running session is not ended by a VPP event and keeps sending its commands, which override the event.
- A discharge cannot be started while the system is off-grid, and a running discharge ends when the system goes off-grid, since an off-grid Powerwall only powers the home. Charge and Preserve charge keep running off-grid.